Troubleshooting CBT_FAILURE in BDRSuite - Quick and Effective Solutions

Troubleshooting CBT_FAILURE in BDRShield

KB ID: 104012
Cause:
The CBT (Changed Block Tracking) driver in BDRShield may become unresponsive due to environmental problems or handle/memory leaks. Additionally, high levels of I/O can lead to extended snapshot quiescing, potentially causing issues in releasing the CBT bitmap file handle.
Solution:
To resolve the CBT_FAILURE issue in BDRShield, follow these steps:
1. Restart the BDRShield Integration service (BIS) running on the Physical Hyper-V Host and reschedule the backup.
2. If using SMB storage, restart the BDRShield Integration service (BIS) on the SMB File Server Host and reschedule the backup.
3. Verify that the BDRShield Integration Service running on both the SMB server and Application Server are using the same domain credentials to start the service.
4. If the problem persists, a CBT reset may be required. This process requires technical expertise, so it is advisable to contact our support team for further assistance.
By following these steps, you can effectively address the CBT_FAILURE issue and ensure smooth backup operations with BDRShield.
    • Related Articles

    • BDRShield - Release Notes

      BDRShield 9.0.0.U2 (Cloud) Release Date: March 12, 2026 Improvements and Fixes Improved validation of email notification settings Enhancements made to chunk file id reset handling for more consistent backup . Internal improvements implemented to ...
    • Troubleshooting Snapshot Failure in BDRShield

      KB ID: 104066 Cause: Users may encounter a "SNAPSHOT_FAILURE" error during snapshot initialization when attempting to back up virtual machines using BDRShield. This issue arises for the following reasons: 1. The clustered volume (CSV) is not ...
    • Title: Backup Success with CBT Failure: Handling Full Resend of VM Data in BDRShield

      KB ID: 105070 Summary: This knowledge base article addresses the scenario where a backup operation is reported as completed successfully, but Change Block Tracking (CBT) fails for a specific VM in BDRShield. This situation arises due to multiple ...
    • Troubleshooting VM Snapshot Operation Failure in BDRShield

      KB ID: 105009 Summary: This knowledge base article addresses the issue of VM snapshot operation failure in Vembu-VMBackup. When encountering this error message, the backup process may fail due to reasons related to snapshot file size exceeding ...
    • Troubleshooting SNAPSHOT_FAILURE: Snapshot Initialization Issue in BDRShield

      KB ID: 115121 Cause: BDRShield backup server relies on the Volume Shadow Copy Service (VSS) to create snapshots. The alert is usually generated when VSS is unable to start due to an ongoing VSS process. Microsoft's native snapshot manager can only ...